NHR-E100 series single-circuit digital display controller

1415954936304105.gif Overview

    NHR-E100 series single-circuit digital display controller is capable of collection, display, control, remote transmission, communication, and printing of site signals including temperature, pressure, liquid level, and speed to form a digital collection system and control system to be widely applied in many fields such as power, petrochemical, metallurgy, light industry, pharmaceutics, and aeronautics.
* Single-way intput, dual-screen LED display with light-beam analog indication (0-100%);
* 36 types of signal input available; input signal type is selectable with measurement precision of 0.2%;
* thermal resistance\thermocouple signal resolution switchable: 1℃ or 0.1℃;
* "Upper/lower-limit alarm", "delayed alarm", "break alarm", and "blink alarm" are available with LED alarm lamp indication;
* Voltage and current transducing output signal is selectable; 
* Supporting RS485 and RS232 serial interfaces, with standard MODBUS RTUcommunication protocol adopted;
* RS232C printing available, cable of manual printing, timed printing, and alarm printing etc;
* DC24V feed output is available for power distribution for transducer on the site;
* Photoelectric isolation technology has been adopted between input, output, power, and communication;
* Multiple sizes and styles are available for user's choice;
* Password lock for parameters setting which would be stored permanently in case of power-off; parameters reset available.

 

1415954936304105.gif Instrument panel

1.gif

2.gif

3.gif

4.gif

160*80mm(Type A)

80*160mm(Type B)

96*48mm(Type D)

48*96mm(Type E)

 

 

 

  

5.gif

6.gif

7.gif

8.gif

96*96mm(Type C)

96*96mm(Type M)

72*72mm(Type F)

48*48mm(Type H)

 

 

 

 

9.gif

10.gif

11.gif

160*80mm(Type K)

80*160mm(Type L)

 

1415954936304105.gif Parameter function

12.jpg

 

_c_ZKZ_pcElAoo55vjDTntNiy0LjtTbJFkI6wzQNCmL5Eo6ERBaRNmEg1GQVML1CuC2HLyEaQUu6NmFFI_Vij2NSA==.jpg

13.jpg

    *Note: The above has given all parameters of the instrument; in case of non-full-featured instrument, parameters for functinos not available will not be specified.
       For example: 

         Note 1: the time display function of the SV screen is initiated only after the printing function is launched.
         Note 2: the fourth alarm mode "disconnection alarm" will be turned on only upon request by customers.

 

1415954936304105.gif Wiring diagram

15.jpg

    Wiring diagram of model A, B, C, D, E, K, L, and M.
             Note: the wiring terminal directions at rear cover of horizontal and vertical instrument are different; see Figure 1.

16.jpg
             Figure 1

17.jpg
       Wiring diagram of model F

_c_nCQFcT9WVwHqdVfY1iYcZvBS1_-i6nDVnZdu8DliTo5RfJ8nrOqEV9XUodpVckMSIG7aW1hzsQkR0uTBnbZpzqIy99cJD65X.jpg
       Wiring diagram of model H

    Note: in the above diagram, if one group of terminals has different functions, only one of them may be available. For example, RS485 and RS232 are on the same group of terminals, so only one of them can be selected.

 

1415954936304105.gif Model selection

QQ圖片20150930103644.png

①Specification

②Input graduation

Code

Width*height*depth

Code

Graduation (Measurement range)

A
B
C
D
E
F
H
K
L
M

160*80*110mm (horizontal)
80*160*110mm (vertical)
96*96*110mm (square)
96*48*110mm (horizontal)
48*96*110mm (vertical)
72*72*110mm (square)
48*48*110mm (square)
160*80*110mm (horizontal/ light beam)
80*160*110mm (vertical/ light beam)
96*96*110mm (square/ light beam)

00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
          19
          20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
55
56

Thermocoupleb (400~1800℃)
Thermocouples (0~1600℃)
Thermocouplek (0~1300℃)
Thermocouple E graduation (0~1000℃)
Thermocouple T graduation (-200.0~400.0℃)
Thermocouple J graduation (0~1200℃)
Thermocouple R graduation (0~1600℃)
Thermocouple N graduation (0~1300℃)
Thermocouple F2 graduation (700~2000℃)
Thermocouple Wre3-25 graduation (0~2300℃)
Thermocouple Wre5-26 graduation (0~2300℃)
Thermal resistance Cu50 (-50.0~150.0℃)
Thermal resistance Cu53 (-50.0~150.0℃)
Thermal resistancecu100 (-50.0~150.0℃)
Thermal resistancept100 (-200.0~650.0℃)
Thermal resistanceba1 (-200.0~600.0℃)
Thermal resistanceba2 (-200.0~600.0℃)
Linear resistance0~500Ω (-1999~9999)
Remote transmission resistance 0~350Ω (-1999~9999)
Remote transmission resistance 30~350Ω (-1999~9999)
0~20mv (-1999~9999)
0~40mv (-1999~9999)
0~100mv (-1999~9999)
-20~20mv (-1999~9999)
-100~100mv (-1999~9999)
0~20ma (-1999~9999)
0~10mA (-1999~9999)
4~20mA (-1999~9999)
0~5V (-1999~9999)
1~5V (-1999~9999)
-5~5V (-1999~9999)
0~10V (-1999~9999)
0~10mA (extraction) (-1999~9999)
4~20mA (extraction) (-1999~9999)
0~5V (extraction) (-1999~9999)
1~5V (extraction) (-1999~9999)
Full switch
Special specification

③Transducing output 1 (OUT 1)

Code

Output type (Load resistanceRL)

X
0
1
2
3
4
5
8

No output
4-20mA (RL≤600Ω)
1-5V (RL≥250KΩ)
0-10mA (RL≤1.2KΩ)
0-5V (RL≥250KΩ)
0-20mA (RL≤600Ω)
0-10V (RL≥4KΩ)
Special specification

④Transducing output 2 (OUT 2)

Code

Output type (Load resistanceRL)

X
0
1
2
3
4
5
8

No output
4-20mA (RL≤600Ω)
1-5V (RL≥250KΩ)
0-10mA (RL≤1.2KΩ)
0-5V (RL≥250KΩ)
0-20mA (RL≤600Ω)
0-10V (RL≥4KΩ)
Special specification

⑤Alarm (Relay contact output)

Code

Limits for alarm

X
1
2
3
4

No output
1-limit alarm
2-limit alarm
3-limit alarm
4-limit alarm

⑥Communication output

Code

Communication interface (Communication protocol)

X
D1
D2
D3

No output
RS-485 Communication interface (Modbus)
RS232 Communication interface (Modbus)
RS232C Printing interface

⑦Feed output

Code

Feed output (Output voltage)

X
1P
2P

No output
1-way feed output
2-way feed output
For example, "2P (12/24)" means first-channel output of 12V and second-channel feed output of 24V.

⑧Power supply

Code

Voltage range

A
D

AC/DC100~240V (AC/50-60Hz)
DC 20~29V

⑨Remarks

N/A, omissible

Remarks:

1. Please select functions based on wiring diagram upon model selection. As terminals of smaller instrument are less than those on bigger ones, only one of several functions may be selected on the same group of terminals.
2. Model F has no RS232C printing interface, and model H has no RS232 communication interface or RS232C printing interface.
3. The contact capacity of the relay of the instruments with specifications and sizes of the D or E mode is AC 125 V/0.5 A and DC 24 V/0.5A in case that there are alarms between terminal 25 and terminal 36 of these instruments, so it is the instruments with specifications and sizes of the H mode, while the relay contact capacity of other instruments is AC 220 V/2 A and DC 24 V/2 A.
4. The model must be written in detail; functions not selected shall not be omitted but marked with "X". Example 1: NHR-E100A-55-0/X/2/D1/1P(24)-A